Applicability of Subheading 9817.00.96, HTSUS, to VADER Pedicle System and VADERone Pedicle System
No revocation or modification of this ruling appears in the Customs Bulletin issues read here (Nov 6, 2024 through Nov 18, 2026), where CBP publishes most such actions. That is not confirmation that the ruling is still in effect. Confirm its status with CBP before relying on it (ruling on CBP CROSS).
Key passages, quoted from the ruling
- The VADER Systems at issue are eligible for duty-free treatment under subheading 4 9817.00.96, HTSUS, as articles specially designed or adapted for the use or benefit of the blind or other physically or mentally handicapped persons.
Ruling text
This is in response to your request, on behalf of icotec AG, dated September 12, 2025, for a binding ruling regarding the eligibility of the VADER Pedicle System and VADERone Pedicle System for subheading 9817.00.96, Harmonized Tariff Schedule of the United States (“HTSUS”), treatment. Our ruling is set forth below. FACTS: icotec AG is an FDA-registered Swiss company that specializes in the development and distribution of spinal implant systems.
The imported merchandise concerns icotec AG’s VADER Pedicle System and VADERone Pedicle System, (together the “VADER Systems”). The VADER Systems are implanted permanently into a patient’s spine to restore the integrity of their spinal columns.
The VADER Systems function similarly except the VADER Pedicle System utilizes fenestrated screws to permit augmented fixation using bone cement injected into the vertebral body after screw placement while the VADERone Pedicle System lacks fenestrated screws and cannot be used with bone cement. The VADER Systems consist of polyaxial pedicle screws and rods, made of icotec AG’s proprietary BlackArmor® carbon-fiber reinforced polyetheretherketone (Carbon/PEEK) and/or titanium alloy.
In addition to the screws and rods, connectors are made of BlackArmor® Carbon/PEEK, and cross-links and nut screws are made of titanium alloy. icotec AG states the VADER Systems work by stabilizing weakened or damaged segments of the spine in patients who have spinal tumors and infections by anchoring BlackArmor® Carbon/PEEK pedicle screws into the vertebrae, which are connected by rods. 1 icotec AG explains that the VADER Systems relieve pressure on the spinal cord and nerves, prevents further collapse or deformity, and enables patients to regain or preserve mobility and function.
Without such intervention, icotec AG submits that those affected would be unable to perform basic life functions, such as standing, sitting upright, and walking, and would possibly be left entirely immobile. icotec AG states that the VADER Systems are used for patients with advanced stage cancerous tumors causing such instability of the spine that spinal fusion surgeries are not an option.
Additionally, the VADER Systems are used for patients with severe spinal infections that impair spinal stability, such as spondylodiscitis and osteomyelitis. The VADER Systems include the following parts, which come in varying sizes to conform to a patient’s spinal structure: nuts, cross links, straight and curved rods, polyaxial screws, and axial and parallel connectors, which are composed of BlackArmor® Carbon/PEEK or titanium alloy.
All parts for the VADER Systems are manufactured by icotec AG solely for use with the VADER Systems and must meet precise specifications and sterility requirements as articles to be implanted permanently in the human body. icotec AG states that there is no other use for the VADER Systems besides the uses noted above and the VADER Systems may only be ordered by a prescribing physician and installed by a surgeon.
ISSUE: Whether the VADER Systems imported by icotec AG are eligible for duty-free treatment under subheading 9817.00.96, HTSUS.
The text above is an excerpt. The official ruling, with its letterhead, signature and any attachments, is on CBP CROSS (H353886).