The country of origin of condensate pumps
No revocation or modification of this ruling appears in the Customs Bulletin issues read here (Nov 6, 2024 through Nov 18, 2026), where CBP publishes most such actions. That is not confirmation that the ruling is still in effect. Confirm its status with CBP before relying on it (ruling on CBP CROSS).
Ruling text
In your letter dated April 16, 2025, you requested a country of origin ruling on a condensate pump. Descriptive information was provided with your submission. The products under consideration are Little Giant’s VCCA-20uls condensate pumps, item numbers 554201101 and 554202101. Item numbers 554201101 and 554202101 feature a plastic enclosure, a float switch, a safety switch, a 1/2-gallon tank capacity, an impeller and a 1/30 horsepower motor.
In use, the condensate pumps automatically collect and remove condensate from air conditioning, refrigeration and dehumidification equipment. With respect to origin, it is explained that the final assembly of each pump occurs in Thailand using components that are sourced from China. Prior to the final assembly, the Chinese sourced components are combined to produce various subassemblies.
The subassemblies produced in Thailand are the overflow detection switch subassembly, the motor subassembly, the float subassembly and the tank cover subassembly. The assembly of the overflow detection switch subassembly, which consists of a micro-switch, a float, and a bracket, begins by screwing a float to a lever. A switch is then inserted into a bracket and snapped in place.
The assembly of the motor subassembly, which is comprised of a motor, motor mounting plate, and a water slinger, consists of screwing a motor mounting plate onto a motor, and is followed by the placement of a water slinger onto the shaft of the motor. The assembly of the float subassembly, which consists of a float, a float pin, and a snap ring, begins by inserting a positioning pin into a bottom mold. A float is then placed on top of the pin and compressed in place.
Afterwards, a snap ring is inserted into the float pin and pressed into position. The tank cover subassembly consists of a tank cover, an operating switch, a micro-switch clip, a float subassembly, a positioning plug and an overflow detection switch subassembly. During the assembly process, a float subassembly is installed into the tank cover and held in place using a snap ring. Next, the operating switch is pressed into the micro-switch clip and the hole in the lever arm of the switch is placed over the float rod.
Afterwards, a positioning plug is installed onto the float pin and a microswitch clip is snapped on the tank cover. Subsequently, the overflow detection switch subassembly is installed into the tank cover and screwed in place. The final assembly of the pump, which takes place in Thailand, begins by screwing a motor subassembly onto a tank cover subassembly. Afterwards, a fan and an impeller are pressed onto the motor shaft using a pneumatic press.
The volute is then pressed and welded onto the bottom of the tank cover. The electrical components (wiring harness, terminals and electrical leads) are connected and a motor cover is installed and screwed in place. Lastly, four feet are installed. Throughout these steps, multiple inspections and tests are conducted. When determining the country of origin for purposes of applying current trade remedies under Section 301 and additional duties, the substantial transformation analysis is applicable.