The tariff classification of desand tank module from Canada
No revocation or modification of this ruling appears in the Customs Bulletin issues read here (Nov 6, 2024 through Nov 18, 2026), where CBP publishes most such actions. That is not confirmation that the ruling is still in effect. Confirm its status with CBP before relying on it (ruling on CBP CROSS).
Ruling text
In your letter dated May 7, 2025, you requested a classification ruling on behalf of your client, Santos Limited – Oil Search (Alaska). The 341 Desand Tank Module (341 Module) is a processing unit that will be installed into the Nanushuk Processing Facility (NPF) in Alaska. The NPF will process oil deposits from the Nanushuk reservoir into sales quality oil. The 341 Module will be installed downstream from the Seawater Treatment Plant which provides seawater injection to subsurface reservoirs in the NPF.
The 341 Module employs a gravitational separation process to separate solids and sediments from four upstream input flows. Desand slurry flowing into the 341 Module is a mixture of water and sand, and small amounts of entrained oil. The first stage of the processing in the 341 Module removes water and oil from the sand. Gravitational separation means that denser sediments from the input slurry will settle in the desand tank, allowing the recovered (supernatant) water to be pumped from the module.
The slurry exiting the bottom of the 341 Module’s tank is of the same composition (water, sand, and oil), but is a more sand heavy mix as bulk water has been removed. These bottom solids are sent (pumped) to a “342 centrifugal feed tank module,” which functions in the same way as the 341 Module, further reducing the water content from the slurry. The classification of the 342 centrifugal tank module will be addressed in a separate ruling, i.e., N348700.
The main components of 341 Module consist of a desand tank, desand tank supernatant pump, and two sludge transfer pumps. The desand tank has a coned bottom that allows solids to sink to the bottom. The 341 Module also includes piping, valves, instrumentation, and all inlets and outlets to-and-from the facility pipe rack. Other components include the desand building, desand tank sample return pump, pump motors, exhaust fan and fan motors, building heaters and heater motors, and an electrical system.
As the NPF is in Alaska, the building heaters and exhaust fans are included to heat the module building and provide air circulation. These do not have an impact on fluid processing. The sludge transfer pumps maintain constant circulation of the slurry, allowing a consistent stream of slurry from the desand tank into the centrifuge feed tank. As heavier particles of the slurry fall to the tank’s bottom, they are pumped out to prevent deposits or blockages from forming.
The desand tank supernatant pump is used to pump the produced water from the tank after the particulates from the slurry are gravitationally separated from the liquid and settled at the tank’s bottom. The supernatant pump is a centrifugal pump. The pumps maintain constant circulation into the desand tank.
In your submission, you suggest the 341 Module should be classified in subheading 8421.21.0000, Harmonized Tariff Schedule of the United States (HTSUS), which provides for “Centrifuges, including centrifugal dryers; filtering or purifying machinery and apparatus, for liquids or gases; parts thereof: Filtering or purifying machinery and apparatus for liquids: For filtering or purifying water.” We disagree.
The text above is an excerpt. The official ruling, with its letterhead, signature and any attachments, is on CBP CROSS (N348699).