The tariff classification of a centrifuge feed tank from Canada
No revocation or modification of this ruling appears in the Customs Bulletin issues read here (Nov 6, 2024 through Nov 18, 2026), where CBP publishes most such actions. That is not confirmation that the ruling is still in effect. Confirm its status with CBP before relying on it (ruling on CBP CROSS).
Ruling text
In your letter dated May 7, 2025, you requested a classification ruling on behalf of your client, Santos Limited – Oil Search (Alaska). The 342 Centrifuge Feed Tank Module (342 Module) is a processing unit that will be installed into the Nanushuk Processing Facility (NPF) in Alaska. The NPF will process oil deposits from the Nanushuk reservoir into sales quality oil. The 342 Module will be installed downstream from the Seawater Treatment Plant which provides seawater injection to subsurface reservoirs in the NPF.
The 342 Module is the second stage of a gravitational separation process to separate solids and sediments from four upstream input flows. In the first stage, a so-called 341 Desand Tank Module (341 Module) receives slurry streams from four sources and performs an initial separation of sediment from water, similarly through gravitational separation.
Gravitational separation means that denser sediments from the input slurry will settle in the centrifuge feed tank, allowing the recovered (supernatant) water to be pumped from the module. Next, sediment is then pumped from the 341 Module into 342 Module which performs the final stage of bulk separation of water from wastewater and sediments that gather from the initial four streams. Material entering the 342 Module has a high solid content as some of the water has already been processed in the 341 Module.
The 342 Module removes the last of the water that can be practically removed through gravity separation, with solids (sludge) at the base of the tank pumped into centrifuges in a separate module. The classification of 341 Desand Tank Module will be addressed in a separate ruling, i.e., N348699. The main components of 342 Module consist of a centrifuge feed tank, centrifuge feed tank supernatant pump, and centrifuge feed pumps. The centrifuge feed tank has a coned bottom that allows solids to sink to the bottom.
The 342 Module relies on density and gravitational separation to separate the supernatant water from any solids. There are no centrifuges included within the composition of the 342 Module. The 342 Module includes piping, valves, instrumentation, and all inlets and outlets to-and-from the facility pipe rack.
Other components include the centrifuge feed tank building, centrifuge feed tank sample return pump, centrifuge feed tank supernatant pump motor, centrifuge feed pump motors, exhaust fans and fan motors, building heaters and their motors, and an electrical system. As the NPF is in Alaska, the building heaters and exhaust fans are included to heat the module building and provide air circulation. These do not have an impact on fluid processing.
The centrifuge feed pumps and motors pump out the bottom of the centrifuge feed tank where the sediments collect. The material that is pumped out is a heavy sand slurry which is predominantly solids, with bulk water removed. The centrifuge feed tank supernatant pump and motor pumps the water from the top of the tank after the particulates have settled at the bottom. The supernatant fluid is then sent to the produced water separator in a separate module.
The text above is an excerpt. The official ruling, with its letterhead, signature and any attachments, is on CBP CROSS (N348700).