The tariff classification of data loggers from China
No revocation or modification of this ruling appears in the Customs Bulletin issues read here (Nov 6, 2024 through Nov 18, 2026), where CBP publishes most such actions. That is not confirmation that the ruling is still in effect. Confirm its status with CBP before relying on it (ruling on CBP CROSS).
Ruling text
In your letter dated May 9, 2025, you requested a tariff classification ruling. Descriptive literature was provided for our review. The first item under consideration is described as the Multi-Use RLT V55 Plus (Part #160-0003), which is a reusable real-time data logger with global 4G/5G LTE connectivity. It uses embedded cellular modems and SIM cards to connect autonomously to the internet and transmit collected data.
The device allows users to verify ambient temperature using the internal device (-30°C to +70°C), external temperature using the probe routed into the package or crate (-200°C to +100°C), humidity (5% RH to 95% RH), shock (1g to 8g), light (0 Lux to 52,000 Lux), tilt (0° to 180°), and GPS location. It is equipped with an auto-flight safe mode that suspends cellular activity during flights. The data logger automatically transmits all data to the CSafe Connect cloud platform via cellular networks.
The device measures 105 mm by 65 mm by 16.9 mm and weighs 130 grams. The second item under consideration is described as the Single-Use RLT V5J Plus (Part #160-0004), which is a single-use version of the Multi-Use RLT V55 Plus. It also contains an integrated 4G/5G LTE cellular module and uses embedded cellular modems and SIM cards to connect autonomously to the internet and transmit collected data.
The device allows users to verify ambient temperature using the internal device (-30°C to +70°C), external temperature using the probe routed into the package or crate (-200°C to +100°C), humidity (5% RH to 95% RH), shock (1g to 8g), light (0 Lux to 52,000 Lux), tilt (0° to 180°), and GPS location. It is equipped with an auto-flight safe mode that suspends cellular activity during flights. The device measures 105 mm by 65 mm by 16.9 mm and weighs 130 grams.
The third item under consideration is described as the TracSafe RLT t72 PRO.1 Meter Probe (Part #160-0001-01), which is a real-time wireless transmission device featuring 4G/5G LTE cellular connectivity. The device allows users to verify ambient temperature using the internal device (-30°C to +70°C), external temperature using the probe routed into the package or crate (-200°C to +100°C), humidity (5% RH to 95% RH), shock (1g to 16g), light (0 Lux to 52,000 Lux), tilt (0° to 180°), and GPS location.
It is equipped with an auto-flight safe mode that suspends cellular activity during flights. The device measures 114 mm x 76.0 mm x 27 mm and weighs 200 grams.
In your letter, you suggest the classification of the Multi-Use RLT V55 Plus (Part #160-0003), the Single-Use RLT V5J Plus (Part #160-0004), and the TracSafe RLT t72 PRO.1 Meter Probe (Part #160-0001-01) to be under heading 8517, Harmonized Tariff Schedule of the United States (HTSUS), which provides in relevant part for: “…other apparatus for the transmission or reception of voice, images or other data, including apparatus for communication in a wired or wireless network (such as a local or wide area network)…”.
We disagree. We find the core function of each sensor to be the measuring/checking. It is the calculated measurement which is of interest to the user.
The text above is an excerpt. The official ruling, with its letterhead, signature and any attachments, is on CBP CROSS (N348855).