The eligibility of long term hemodialysis catheters under the Nairobi Protocol treatment from Mexico
No revocation or modification of this ruling appears in the Customs Bulletin issues read here (Nov 6, 2024 through Nov 18, 2026), where CBP publishes most such actions. That is not confirmation that the ruling is still in effect. Confirm its status with CBP before relying on it (ruling on CBP CROSS).
Ruling text
In your letter dated May 16, 2025, you requested a tariff classification ruling for the following long-term hemodialysis catheters: Hemo Cath® LT Catheter, Split Cath® III Catheter, Tesio® Catheter, Duo-Jet®II Chronic Twinline Catheter, Split Stream® Catheter, and Canaud Catheter. They are designed specifically for use in patients with chronic kidney disease requiring ongoing hemodialysis. Additional information was provided via email dated July 14 and July 21, 2025.
The Hemo Cath® LT Catheter is a double lumen, single access catheter that is used to remove and return blood through two separate passages (venous and arterial lumens). It is available in 8F, 10F, and 12.5F straight configurations, as well as a pre-curved option, all featuring a step-tip design which refers to the staggered configuration in which the venous lumen extends further distally than the arterial lumen at the tip of the tube. Each lumen is connected through an extension line.
The transition between lumen and extension is housed within a molded hub. Each lumen has the priming volume identified by identification rings assembled into the clamps on the extensions. A polyester Dacron cuff is placed on the catheter’s lumen for tissue ingrowth to anchor the catheter. The catheter incorporates barium sulphate to facilitate visualization under fluoroscopy or x-ray. It also includes a suture wing, two sleeves, and two Luer-Lok connectors.
The Split Cath® III Catheter (straight and pre-curve) is a double lumen, single access catheter that is used to remove and return blood through two separate passages (venous and arterial lumens). It utilizes a split-tip design which refers to the configuration where the distal end of the catheter is divided into two separate tips. The venous lumen is positioned slightly further than the arterial lumen of the catheter. Each lumen is connected through an extension line.
The transition between lumen and extension is housed within a molded hub. Each lumen has the priming volume identified by identification rings assembled into the clamps on the extensions. A polyester Dacron cuff is placed on the catheter’s lumen for tissue ingrowth to anchor the catheter. The catheter incorporates barium sulphate to facilitate visualization under fluoroscopy or x-ray. It also includes a rotatable suture wing, two sleeves, and two Luer-Lok connectors.
The Tesio® Catheter is a single-lumen catheter available in 40 cm and 70 cm assembled versions, and a 40 cm unassembled version inserted into the target vein that is used to remove or return blood. It utilizes a round lumen tip design which refers to the rounded, smooth arterial lumen or venous lumen tip of the catheter. The body of the catheter has depth markings and a Dacon cuff.
The catheter includes a separate arterial or venous extension set, color-coded for identification (red for arterial and blue for venous), which consists of a hub, a tube, a clamp, an ID ring, and a Luer-Lok connector. The catheter incorporates barium sulphate to facilitate visualization under fluoroscopy or x-ray.
The text above is an excerpt. The official ruling, with its letterhead, signature and any attachments, is on CBP CROSS (N350729).