The classification and country of origin of a heat pump
No revocation or modification of this ruling appears in the Customs Bulletin issues read here (Nov 6, 2024 through Nov 18, 2026), where CBP publishes most such actions. That is not confirmation that the ruling is still in effect. Confirm its status with CBP before relying on it (ruling on CBP CROSS).
Ruling text
In your letter dated June 30, 2025, on behalf of your client, KD Navien, you requested a classification and country of origin ruling for marking purposes. The heat pump, model number GDHP820035DR1, is an outdoor unit. The outdoor unit consists of a chassis that incorporates a compressor, a condenser, a motor and fan assembly, a four-way reversing valve, an expansive valve assembly, a control panel and an accumulator. Once paired with an indoor unit, which is imported separately, the system heats and cools spaces.
The applicable subheading for the heat pump will be 8415.90.8065, Harmonized Tariff Schedule of the United States (HTSUS), which provides for Air conditioning machines, comprising a motor-driven fan and elements for changing the temperature and humidity, including those machines in which the humidity cannot be separately regulated; parts thereof: Parts: Other: Other: Of heat pumps. The general rate of duty is 1.4 percent ad valorem.
With respect to origin, the final assembly of the heat pump occurs in South Korea using components sourced from China. The final assembly begins by installing rubber grommets onto the bottom of a compressor. The compressor, along with an accumulator, is fastened to the base of the chassis. Afterwards, a crankshaft heating tape is secured to the bottom section of the compressor, and the input wire is connected.
Next, valve assemblies are positioned and bolted in place, and the inlets and outlets of the compressor and the accumulator are brazed. Subsequently, an expansion valve assembly is secured to a support plate using two anti-vibration rubbers and cable ties. Then, the inlets and outlets of the hairpin pipes are connected to the condenser and subsequently brazed.
In the next step, the condenser is screwed to the base frame, brazing is completed, and three corner panels, along with the side panel, are screwed onto the base. Wiring connections are then completed, a plastic cover is secured in place, and auxiliary components, such as temperature sensors, a sound jacket, solenoid valves, and insulation materials are installed. During the following steps, a vacuum process occurs, and the unit is charged and sealed.
Lastly, a fan assembly and a main control panel are installed, a top cover is secured, and wire connections are affixed.
Section 304 of the Tariff Act of 1930, as amended (19 U.S.C. 1304), provides that unless excepted, every article of foreign origin imported into the United States shall be marked in a conspicuous place as legibly, indelibly, and permanently as the nature of the article (or its container) will permit, in such a manner as to indicate to the ultimate purchaser in the United States, the English name of the country of origin of the article.
Congressional intent in enacting 19 U.S.C. 1304 was “that the ultimate purchaser should be able to know by an inspection of the marking on the imported goods the country of which the goods is the product.
The text above is an excerpt. The official ruling, with its letterhead, signature and any attachments, is on CBP CROSS (N350773).