The tariff classification of components of a heat exchanger sub-assembly from Canada
No revocation or modification of this ruling appears in the Customs Bulletin issues read here (Nov 6, 2024 through Nov 18, 2026), where CBP publishes most such actions. That is not confirmation that the ruling is still in effect. Confirm its status with CBP before relying on it (ruling on CBP CROSS).
Key passages, quoted from the ruling
- The applicable subheading for the stainless-steel tubes will be 7306.40.1090, HTSUS, which provides for other tubes, pipes and hollow profiles (for example, open seamed or welded, riveted or similarly closed), of iron or steel: other, welded, of circular cross section, of stainless steel: having a wall thickness of less than 1.65 mm: other.
- The rate of duty will be free. tubes On March 12, 2025, Presidential proclamations 10895 and 10896 imposed additional tariffs on products of steel and aluminum.
Ruling text
In your letter dated July 29, 2025, you requested a tariff classification ruling on behalf of Samuel, Son & Company. The merchandise under consideration is described as a Heat Exchanger Sub-assembly, Model # 336770-707. Each sub-assembly consists of 1 containment plate, 1 liner tube sheet, 45 tubes, and 45 turbulators - all made of stainless steel. The components are shipped individually in bulk shipping containers in the required quantities of components needed to create the total number of sub-assemblies ordered.
The components are not imported in retail packaging. The containment plate is used to secure the tubes within the heat exchanger. The liner tube sheet is a plate with a specific number of holes that serves to support and isolate the heat exchanger tubes. The turbulators are helically shaped rods that are inserted into the tubes, where they create turbulence of the circulating airflow. The stainless-steel tubes are cold-formed, welded, annealed, and cut-to-length.
These tubes have a wall thickness of 0.305 mm, an inside diameter of 12.21 mm, and an outside diameter of 12.77 mm. You state that the tubes isolate the combustion air from the warmed residential household air which is where the exchange of heat occurs. You note that the completed secondary heat exchanger is a crucial component in a heating system. It is situated between a primary heat exchanger and a blower module in a gas-fired air furnace.
The furnace heats air that is pushed by a blower module upwards and then into the ducting of a structure. In your submission, you suggest that the containment plate, liner tube sheet, turbulators, and stainless-steel tubes are classified under subheading 8419.90.3000, Harmonized Tariff Schedule of the United States (HTSUS), as parts of a heat exchange unit. We disagree. Before we can classify the individual components, we must determine the classification of the article in which they are used.
The items are components of a secondary heat exchanger in a gas-fired air furnace. While referred to as a “heat exchanger,” it is not a machine for treating materials, nor is it configured so that one fluid is cooled and another is heated. Rather, it needs to be combined with a primary heat exchanger and a blower module to complete its function, which is to act as a heating coil.
Because the secondary heat exchanger is not configured as a heat exchanger of heading 8419, the aforementioned items are not classified as parts of a machine of heading 8419. As imported, the containment plate, liner tube sheet, turbulators are specifically provided for in heading 7322, HTSUS, and welded tubes are specifically provided for in heading 7306, HTSUS.
The text above is an excerpt. The official ruling, with its letterhead, signature and any attachments, is on CBP CROSS (N351783).