The tariff classification of a coolant hub module from South Korea
No revocation or modification of this ruling appears in the Customs Bulletin issues read here (Nov 6, 2024 through Nov 18, 2026), where CBP publishes most such actions. That is not confirmation that the ruling is still in effect. Confirm its status with CBP before relying on it (ruling on CBP CROSS).
Key passages, quoted from the ruling
- Accordingly, the applicable subheading for the coolant hub module will be 8413.70.2005, HTSUS, which provides for Pumps for liquids, whether or not fitted with a measuring device; liquid elevators; part thereof: Other centrifugal pumps: Other: Other: Single-stage, single-suction, close-coupled: With discharge outlet under 5.08 cm in diameter.
Ruling text
In your letter dated July 29, 2025, you requested a tariff classification ruling on behalf of your client, Myunghwa Industry Co. Ltd. Descriptive information was submitted for review. The product at issue is a coolant hub module, item number 25429-CV500, which is referred to as a vehicle coolant reservoir.
The module, which is part of a cooling system used in an electric vehicle, is a composite good that consists of two single suction water pumps, a reservoir with a 2.2. liter capacity, a three-way valve, and various hoses and mounting brackets. In use, the closed coupled pumps discharge coolant stored in the reservoir out of 1.89-centimeter outlets to dissipate heat released by the battery system and various electrical systems.
In your letter, you suggest the module is classified within subheading 8708.99.8180, Harmonized Tariff Schedule of the United States (HTSUS), which provides for Parts and accessories of the motor vehicles of headings 8701 to 8705: Other parts and accessories: Other: Other: Other: Other: Other: Other. We disagree. While the module is used in an electrical vehicle, it is not an integral component part of the vehicle.
It is an integral component part of a cooling system that is used to cool components in a vehicle, and therefore, the module is excluded from heading 8708. Goods that are, prima facie, classifiable under two or more headings, are classifiable in accordance with General Rule of Interpretation (GRI) 3, HTSUS.
GRI 3(a) states in part, when two or more headings each refer to part only of the materials or substances contained in mixed or composite goods, those headings are to be regarded as equally specific, even if one heading gives a more precise description of the good.
Goods classifiable under GRI 3(b) are classified as if they consisted of the material or component which gives them their essential character, which may be determined by the nature of the material or component, its bulk, quantity, weight or value, or by the role of a constituent material in relation to the use of the article. In this case, the pumps impart the essential character of the module, as they release coolant that lowers the temperature of various systems.
Pumps that transfer fluid are provided for within heading 8413. Accordingly, the applicable subheading for the coolant hub module will be 8413.70.2005, HTSUS, which provides for Pumps for liquids, whether or not fitted with a measuring device; liquid elevators; part thereof: Other centrifugal pumps: Other: Other: Single-stage, single-suction, close-coupled: With discharge outlet under 5.08 cm in diameter. The general rate of duty will be Free.
Effective April 5, 2025, Executive Orders implemented “Reciprocal Tariffs.” All imported merchandise must be reported with either the Chapter 99 provision under which the reciprocal tariff applies or one of the Chapter 99 provisions covering exceptions to the reciprocal tariffs. At this time, products of South Korea will be subject to an additional ad valorem rate of duty of 15 percent.
The text above is an excerpt. The official ruling, with its letterhead, signature and any attachments, is on CBP CROSS (N351805).