The country of origin of a heat pump
No revocation or modification of this ruling appears in the Customs Bulletin issues read here (Nov 6, 2024 through Nov 18, 2026), where CBP publishes most such actions. That is not confirmation that the ruling is still in effect. Confirm its status with CBP before relying on it (ruling on CBP CROSS).
Ruling text
In your letter dated July 31, 2025, you requested a country of origin ruling on a heat pump, on behalf of your client, KD Navien. Descriptive information was submitted for our review. The heat pump (Model No. GDHP65036TC3) primarily consists of a chassis that encases a compressor, a heat exchange unit, a motor and fan assembly, valve assemblies, a control panel and an accumulator. Once paired with an indoor unit, which is imported separately, the system heats and cools spaces.
With respect to origin, the final assembly occurs in South Korea using components from China. Prior to the final assembly process, coils of copper tubes sourced from China are fed into a U-bend forming machine in South Korea to be cut and shaped. Next, flat fin-tube assemblies that are rectangular in shape are bent into shape. Lastly, the U-shaped tubes, inlets and outlets are brazed onto the shaped fin-tube assemblies to produce a heat exchange unit that functions as a condenser or an evaporator.
The final assembly begins by installing rubber grommets onto the bottom of a compressor. Next a compressor and an accumulator are positioned and fastened onto a base using bolts. During the following step, heating tape is bolted in place and a high-pressure pipe assembly is fastened in position using two bolts. Then, a compressor return pipe is assembled and connected to the outlet of an accumulator and the inlet of the compressor.
Afterwards, a pipe from a four-way valve assembly is positioned to the exterior of the unit, the inlets and outlets of the compressor and accumulator are brazed into position, and an electronic expansion valve (EEV) assembly is secured to a support plate. Next, a heat exchanger unit is screwed onto the base and subjected to brazing processes at the points in which the service valve assembly connects to the EEV assembly, the EEV assembly connects to the condenser pipe, and the copper pipes between the EEV assembly.
Once the brazing processes are complete, the outer panels are connected to the base and secured in place using screws. Subsequently, a plastic cover is positioned, and auxiliary components, such as sensors, a sound jacket, an EEV coil and solenoid valves are installed. The unit then undergoes a vacuum process, followed by a charging process. Finally, a fan assembly and a main control panel are installed and secured in place.
When determining the country of origin for purposes of applying current trade remedies under Section 301 and additional duties, the substantial transformation analysis is applicable. See, e.g., Headquarters Ruling Letter H301619, dated November 6, 2018. The test for determining whether a substantial transformation will occur is whether an article emerges from a process with a new name, character, or use different from that possessed by the article prior to processing.
See Texas Instruments Inc. v. United States, 681 F.2d 778 (C.C.P.A. 1982). This determination is based on the totality of the evidence. See National Hand Tool Corp. v. United States, 16 C.I.T. 308 (1992), aff’d, 989 F.2d 1201 (Fed. Cir. 1993). Additionally, Section 304 of the Tariff Act of 1930, as amended (19 U.S.C.
The text above is an excerpt. The official ruling, with its letterhead, signature and any attachments, is on CBP CROSS (N351860).