The tariff classification of gluten detection capsules and detection systems from China
No revocation or modification of this ruling appears in the Customs Bulletin issues read here (Nov 6, 2024 through Nov 18, 2026), where CBP publishes most such actions. That is not confirmation that the ruling is still in effect. Confirm its status with CBP before relying on it (ruling on CBP CROSS).
Key passages, quoted from the ruling
- In both subheadings, the general rate of duty will be free.
Ruling text
In your letter dated November 13, 2025, on behalf of your client, NIMA Partners, Inc., you requested a tariff classification ruling. The samples were received, examined, and disposed of. The first item under consideration is described as the single-use Gluten Detection Capsule. Each Capsule contains a lateral flow antibody test strip with two proprietary antibodies designed to detect gluten, a proprietary extraction buffer, and spindle-shaped features. The cap of the Capsule has teeth-shaped features.
When the cap is screwed down, it helps to grind the food and release the extraction buffer. The Capsule must be inserted into the Sensor to complete the gluten detection test. Each Capsule measures 2.5 × 0.8 × 0.6 inches and weighs 0.05 lbs.
The second item under consideration is the Gluten Detection Sensor, which is a compact, triangular electronic device that contains internal mechanisms to mix the food sample with the extraction buffer and then analyze the antibody test strip by using its optical system to detect a fluorescent signal produced when the gluten binds with the antibodies. The Sensor evaluates this signal through proprietary algorithms and displays results within approximately four minutes.
Results may also be viewed through the NIMA Partners mobile application. The Sensor includes an OLED display, printed circuit board assembly, optics assembly, mixing motor, housing components, and associated mechanical hardware. It measures 3.5 x 0.8 x 3 inches and weighs 0.16 lbs. To conduct a test, the user inserts a food sample into the Capsule and secures the cap, initiating an initial grinding step.
When the Capsule is placed into the Sensor, the Sensor’s motor engages a magnetic clutch, further mixing the sample with the extraction buffer. The extraction buffer breaks down the food and releases gluten proteins into the solution. After mixing, a compliant mechanism in the Capsule opens the foil liner within the Capsule, allowing the prepared solution to flow up the antibody strip through capillary action.
If gluten is present at or above 10 parts per million (ppm), the two proprietary antibodies and conjugation chemistry then binds with gluten proteins, generating a fluorescent signal. The Sensor then displays a wheat icon if there is gluten in the food sample. If gluten is absent or below this threshold, a smiley face appears, indicating that no gluten is present in the food sample.
In your letter, you suggest the applicable subheading for the Gluten Detection Capsule to be 3822.19.0030, Harmonized Tariff Schedule of the United States (HTSUS), which provides for “Diagnostic or laboratory reagents on a backing, prepared diagnostic or laboratory reagents whether or not on a backing, whether or not put up in the form of kits, other than those of heading 3006; certified reference materials: Diagnostic or laboratory reagents on a backing, prepared diagnostic or laboratory reagents whether or not on a backing, whether or not put up in the form of kits: Other: Containing antigens or antisera: Other.” However, the complete ingredient breakdown was not provided.
The text above is an excerpt. The official ruling, with its letterhead, signature and any attachments, is on CBP CROSS (N356022).