The tariff classification of a regenerative emulator from Malaysia
No revocation or modification of this ruling appears in the Customs Bulletin issues read here (Nov 6, 2024 through Nov 18, 2026), where CBP publishes most such actions. That is not confirmation that the ruling is still in effect. Confirm its status with CBP before relying on it (ruling on CBP CROSS).
Ruling text
In your letter dated February 11, 2026, you requested a tariff classification ruling. Descriptive literature was provided for our review. The item under consideration is described as the SL1200A Series Regenerative 3Phase AC Emulator, which is a high-power, bidirectional grid simulation system designed specifically for testing electric vehicle charging infrastructure (EVSE), electric vehicle (EV) onboard chargers, and grid-edge applications like solar photovoltaic (PV) inverters and energy storage systems.
It provides comprehensive testing capabilities up to 1200 volts alternating current (VAC) and power levels ranging from 30 kW to 810 kW (up to 1.08 mega-volt-ampere (MVA) when paralleled) without requiring an external transformer. As a 100% regenerative and bidirectional system with over 85% efficiency, it enables energy-saving, four-quadrant power operation, making it ideal for simulating real-world grid conditions, including harmonic injection and high-voltage ride-through (HVRT) tests.
The system features power outputs from 42 kVA to 135 kVA and voltage ranges of 600 VAC and 1200 VAC. The system allows for dual-ranges that allow for both low and high-voltage testing in the same footprint. The series is controlled via an intuitive Soft Front Panel (SFP) and supports automation of complex grid compliance standards such as IEEE 1547 and UL 1741 SB.
The SL1200A AC emulator measures voltage and current during testing by simulating AC power conditions and analyzing how a device under test behaves in response. The emulator monitors the voltage levels provided to the device being tested, ensuring that the desired output matches the set values. It can simulate various voltage conditions, like fluctuations, to test the device’s performance and stability. The emulator also measures the current drawn by the device, helping assess its efficiency and power consumption.
It can analyze how the device reacts to changes in current, such as spikes or variations in load. The SL1200A AC emulator does not include a recording device or internal memory and therefore cannot store measurement results internally. Instead, all measurement data is stored externally in the memory of the connected computer.
As you suggest in your letter, the applicable subheading for the SL1200A Series Regenerative 3Phase AC Emulator will be 9030.33.3800, Harmonized Tariff Schedule of the United States (HTSUS), which provides for “Oscilloscopes, spectrum analyzers and other instruments and apparatus for measuring or checking electrical quantities, excluding meters of heading 9028; instruments and apparatus for measuring or detecting alpha, beta, gamma, X-ray, cosmic or other ionizing radiations; parts and accessories thereof: Other instruments and apparatus, for measuring or checking voltage, current, resistance or power (other than those for measuring or checking semiconductor wafers or devices): Other, without a recording device: Other.” The general rate of duty will be free.
The duties cited above are current as of this ruling’s issuance. Duty rates are provided for your convenience and are subject to change.
The text above is an excerpt. The official ruling, with its letterhead, signature and any attachments, is on CBP CROSS (N358783).