The tariff classification of RFID measuring devices from Austria
No revocation or modification of this ruling appears in the Customs Bulletin issues read here (Nov 6, 2024 through Nov 18, 2026), where CBP publishes most such actions. That is not confirmation that the ruling is still in effect. Confirm its status with CBP before relying on it (ruling on CBP CROSS).
Ruling text
In your letter dated March 6, 2026, you requested a tariff classification ruling. Descriptive literature was provided for our review. The first item under consideration is described as the CISC RFID Xplorer, which is a compact, high-precision Ultra High Frequency (UHF) Radio-frequency identification (RFID) test and measurement instrument. It is used for performance and conformance testing of UHF RFID readers and tags, operating from approximately 700 MHz to 1.2 GHz.
The device measures tag sensitivity, communication range, backscatter power, tag radiation patterns, and conformance parameters, offering modes for tag performance, reader testing, and RF signal analysis. A real-time sniffer records and decodes reader–tag communication, including protocol and spectrum analysis. This product is not a communication device; instead, it generates controlled RF test signals and evaluates RFID responses for laboratory, engineering, and certification use.
It is controlled via a PC using a graphical user interface (GUI) or application programming interface (API) over Ethernet, serving RFID developers, test laboratories, and manufacturers. The second item under consideration is described as the CISC RAIN Xplorer Inline 100, which is a high-speed UHF RFID testing device designed for automated production lines manufacturing RAIN RFID inlays and labels.
It performs real-time testing of RAIN RFID tags, including reading, writing, encoding, and sensitivity measurements, at high throughput rates. Operating in the UHF band (approximately 800–1000 MHz), it supports adjustable transmit power, Electronic Product Code (EPC) and Tag Identifier (TID) reads, and frequency-dependent sensitivity testing. Designed for industrial integration, it communicates with machine controllers via Universal Serial Bus (USB) and General-Purpose Input/Output (GPIO) interfaces.
This product does not perform network communication or modem functions; it generates controlled RFID test signals solely for quality inspection in production and quality assurance environments. The third item under consideration is described as the CISC NFC Xplorer 110, which is a compact High Frequency (HF) RFID and Near Field Communication (NFC) test and measurement system for performance and conformance testing of NFC devices and tags.
Functioning as both an active transmitter-receiver and a high-precision analyzer at 13.56 MHz, it provides measurements such as load modulation amplitude, minimum activation field strength, RF envelope characteristics, and protocol-level decoding for multiple NFC and HF RFID standards (e.g., ISO 14443 A/B, ISO 15693/180003, ISO 18092). A real-time sniffer mode allows detailed examination of reader–tag communication.
This product is not a communication device; it generates controlled RF test signals and analyzes NFC/HF RFID responses for engineering, certification, and laboratory use. Controlled via Ethernet, it is utilized by NFC/RFID developers, test laboratories, and certification bodies.
The text above is an excerpt. The official ruling, with its letterhead, signature and any attachments, is on CBP CROSS (N359501).