The country of origin of pulse oximetry sensors
No revocation or modification of this ruling appears in the Customs Bulletin issues read here (Nov 6, 2024 through Nov 18, 2026), where CBP publishes most such actions. That is not confirmation that the ruling is still in effect. Confirm its status with CBP before relying on it (ruling on CBP CROSS).
Key passages, quoted from the ruling
- Therefore, the country of origin of the Low Noise Cabled Sensors (both the wrap around and the fold over styles) will be the United States.
Ruling text
In your letter dated March 6, 2026, on behalf of your client, Masimo Corporation, you requested a country of origin ruling on pulse oximetry sensors. Descriptive literature was provided for our review. The items under consideration are described as Low Noise Cabled Sensors (LNCS), which are oxygen saturation sensors used in medical settings to monitor a patient’s oxygen levels. The first sensor is a wrap-around style sensor (SKU number 1862) and the second is a fold-over style sensor (SKU number 2329).
While both sensors attach to patients in distinct ways, both styles rely on the same sensor components. The wrap-around sensors are placed on a patient by wrapping it around a finger, toe, thumb, hand, or foot. They are attached with a connector and cable. Wrap-around sensors are available in adult, pediatric, infant, and neonatal sizes. The fold-over sensors are placed over a patient’s finger or toe and are then attached with a connector and cable.
The design research, product development, and materials selection for both types of sensors take place in the United States and are functionally composed of a component array, with two primary functional components. The first is an emitter component made up of two light-emitting diodes (LED) electrically connected into one subassembly. The emitter is made of a U.S.-origin leadframe, LED chips, and epoxy, and Japanese-origin bonding wire and transfer mold compound.
The second is a photodetector component featuring a photodiode electrically connected to a base to form a photodetector subassembly. The detectors are made of U.S.- origin epoxy, a Malaysian-origin leadframe, a Taiwanese or Malaysian origin photodiode chip, and Japanese-origin transfer mold compound and bonding wire. The emitter component and detector component are further electrically connected to form a sensor array.
That sensor array is then further attached to other materials, including a Chinese-origin cable and connector assembly, and a U.S.-origin adhesive film tape enclosure. Then, either a second film-based adhesive applicator tape, a woven fabric with adhesive applicator tape, or a Velcro-based fabric applicator tape is applied. In operation, the emitter array is positioned on one side of the application site, while the detector array is positioned on the opposite side.
One LED in the emitter component emits infrared light, and the other emits red light. The detector component then measures the amounts of infrared and red light that pass through the patient. Given that oxygenated blood absorbs more infrared light, and deoxygenated blood absorbs more red light, the detector measurements can be used to calculate the patient’s blood oxygen percentage. The emitter half of the sensor array is assembled in the United States from U.S.-origin LEDs.
This U.S. emitter component manufacturing involves taking a pair of U.S.-origin LEDs, and electrically connecting them, resulting in a discrete specialized emitter component specifically designed for further assembly into the completed sensor array. The detector component half of the sensor is also assembled in the United States. It is made with a generic photodiode from Taiwan or Malaysia.
The text above is an excerpt. The official ruling, with its letterhead, signature and any attachments, is on CBP CROSS (N359536).