The tariff classification, country of origin, and trade program status of a prefabricated building structure
No revocation or modification of this ruling appears in the Customs Bulletin issues read here (Nov 6, 2024 through Nov 18, 2026), where CBP publishes most such actions. That is not confirmation that the ruling is still in effect. Confirm its status with CBP before relying on it (ruling on CBP CROSS).
Key passages, quoted from the ruling
- The applicable subheading for the prefabricated building structures will be 9406.90.0130, HTSUS, which provides for Prefabricated buildings: Other: Of metal: Other.
- The general rate of duty will be 2.9 percent ad valorem.
Ruling text
In your letter, dated February 24, 2026, you requested a binding tariff classification, country of origin, and applicability of trade programs ruling on a prefabricated building structure. The request was returned to you for additional information, which was received by this office on March 16, 2026. Product information and diagrams were submitted for our review. The product under consideration is a prefabricated building structure for residential construction.
The structure is constructed of cold-formed steel structural members including wall studs, tracks, floor joists, and roof trusses. The wall panels are constructed of cold-formed steel studs and tracks with magnesium oxide sheathing boards and various types of insulation. The floor structure is constructed of cold-formed steel joists. You state that “the prefabricated wall panels incorporate exterior sheathing, insulation systems, and mechanical, electrical, and plumbing rough-in components prior to shipment.
Exterior wall panels are configured to receive exterior cladding on site, while interior finishes are completed after installation and final utility connections.” You state that “(e)lectrical conduit and wiring, plumbing piping, and HVAC pathways may be installed within the cold formed steel wall cavities during panel fabrication.” You also state that interior finishes are installed after the structural building has been erected in the U.S. The structures are not imported with furniture or appliances.
The components are entered together ready to assemble into a prefabricated building structure. The materials are not adapted to general use. The units are not modular units that are assembled together to form a larger structure.
Note 4 to Chapter 94, Harmonized Tariff Schedule of the United States (HTSUS) defines “prefabricated buildings”: For the purposes of heading 9406, the expression "prefabricated buildings" means buildings which are finished in the factory or put up as elements, entered together, to be assembled on site, such as housing or worksite accommodation, offices, schools, shops, sheds, garages or similar buildings.
The Explanatory Notes to the Harmonized System for Chapter 94 set for that prefabricated buildings are in the form of - complete buildings, fully assembled, ready for use; - complete buildings, unassembled; - incomplete buildings, whether or not assembled, having the essential character of prefabricated buildings.
In the case of buildings presented unassembled, the necessary elements may be presented partially assembled (for example, walls, trusses) or cut to size (beams, joists, in particular) or, in some cases, in indeterminate or random lengths for cutting on the site (sills, insulation, etc.). The instant units are finished in the factory and entered together to be assembled onsite into housing units. They include trusses, wall panels (with steel framing), and joists.
While the finishing is completed in the United States, the imported goods have the essential character of prefabricated buildings.
The text above is an excerpt. The official ruling, with its letterhead, signature and any attachments, is on CBP CROSS (N359753).