The tariff classification of an industrial water cooling tower from South Korea
No Headquarters ruling in this index revokes or modifies this ruling. That is not confirmation that it is still in effect: this index does not hold every Headquarters ruling. Confirm its current status with CBP before relying on it (ruling on CBP CROSS). Text last read from CBP on Nov 21, 2026.
Ruling text
In your letter dated August 20, 2026, you requested a tariff classification ruling on behalf of your client, Seongdo USA Inc. The merchandise under consideration is an industrial steel water cooling tower, model number OTTX-350L, with an induced-draft, cross-flow, and open-circuit design. It features a cold-water basin, a hot-water basin, and dual vertical fill banks mounted in a structural frame enclosed by panels.
During its operation, hot process water is piped to the top of the unit, where it is distributed by gravity over PVC packing in the fill banks, which are located on opposite sides of the unit. At the top of the unit is an induced-draft fan assembly equipped with an axial air-foil fan. The fan draws ambient air into the unit, where it flows perpendicular to the falling water and then passes through drift eliminators before exiting the tower.
As the water and air make direct contact, heat is transferred through evaporation. The cooled water collects in the cold-water basin at the base and returns to the process equipment. This unit has a cooling capacity of 1,070,400 kcal per hour and measures approximately 2.4 meters in length, 4.9 meters in width, and 3.29 meters in height. In your submission, you suggest that the subject cooling tower is classifiable in heading 8419, Harmonized Tariff Schedule of the United States (HTSUS). We agree.
The applicable subheading for the industrial water cooling tower, model number OTTX-350L, will be 8419.89.9540, HTSUS, which provides for “Machinery, plant or laboratory equipment, whether or not electrically heated (excluding furnaces, ovens and other equipment of heading 8514), for the treatment of materials by a process involving a change of temperature such as heating, cooking, roasting, distilling, rectifying, sterilizing, pasteurizing, steaming, drying, evaporating, vaporizing, condensing or cooling, other than machinery or plant of a kind used for domestic purposes; instantaneous or storage water heaters, nonelectric; parts thereof: Other machinery, plant or equipment: Other: Other: Other: Other: Designed for cooling: Other.” The general rate of duty will be 4.2 percent ad valorem.
Duty rates are provided for your convenience and are subject to change. The text of the most recent HTSUS and the accompanying duty rates are provided at https://hts.usitc.gov/. This ruling does not address the applicability of any additional duties, taxes, fees, exactions and/or other charges, which may apply to the goods discussed herein. This includes, but is not limited to, tariffs and other duties as provided for in Subchapter III to Chapter 99, HTSUS.
Thus, for example, in addition to the classification stated above, the merchandise covered by this ruling may also need to be reported with either the Chapter 99 provision under which an additional tariff applies or one of the Chapter 99 provisions covering exceptions to such tariffs.
The text above is an excerpt. The official ruling, with its letterhead, signature and any attachments, is on CBP CROSS (N364449).