The tariff classification of a heat exchange wall unit from Canada
No revocation or modification of this ruling appears in the Customs Bulletin issues read here (Nov 6, 2024 through Nov 18, 2026), where CBP publishes most such actions. That is not confirmation that the ruling is still in effect. Confirm its status with CBP before relying on it (ruling on CBP CROSS).
Key passages, quoted from the ruling
- The applicable subheading for the heat exchange unit will be 7616.99.5190, HTSUS, which provides for “Other articles of aluminum: Other: Other: Other: Other: Other: Other.” The general rate of duty will be 2.5 percent ad valorem.
Ruling text
In your letter dated September 17, 2026, you requested a tariff classification ruling. Informational material was submitted with your request. The merchandise under consideration is a heat exchange unit, identified as Twa Aluminum Plate-Fin Heat Exchange Unit 2H, used to heat the air within an indoor space. The unit is made of metal (aluminum, copper, and steel), is rectilinear in shape, and measures approximately 8 feet in length, 10 inches in height, and 7.5 inches in depth.
It can be mounted on a wall or pedestal and integrated with other units powered through a building’s central boiler or heat pump system. The components include a natural convection coil (Part # COLE-84-0C1H) and metal panels that enclose the coil to distribute heat. The natural convection coil is the main component that generates the heat for this system. It consists of a copper tube enclosed by a louvered grate made of closely spaced aluminum sheet fins.
It is roughly the same size and shape as the overall unit but slightly smaller because it is designed to be enclosed by the panels completing the heat exchange unit assembly. The copper tube within runs continuously along the length of the coil multiple times with its two ends extended out on one side. When heated water circulates through the copper tube, the tube heats up and transfers the heat to the aluminum fins.
As this happens air passes through the fins and heats the air which is then distributed to the indoor space.
In your submission, you suggest that the heat exchange unit is classifiable under subheading 8419.50.5000, Harmonized Tariff Schedule of the United States (HTSUS), which provides for “Machinery, plant or laboratory equipment, whether or not electrically heated (excluding furnaces, ovens and other equipment of heading 8514), for the treatment of materials by a process involving a change of temperature such as heating, cooking, roasting, distilling, rectifying, sterilizing, pasteurizing, steaming, drying, evaporating, vaporizing, condensing or cooling, other than machinery or plant of a kind used for domestic purposes; instantaneous or storage water heaters, nonelectric; parts thereof: Heat exchange units: Other.” We disagree.
The heat exchange unit is not a machine. It is a hydronic heater that is installed to provide convective and radiant heating to indoor spaces. As such, the heat exchange unit is precluded from classification in heading 8419, HTSUS.
General Rule of Interpretation (GRI) 3(b) which provides “that mixtures, composite goods consisting of different materials or made up of different components, and goods put up in sets for retail sale shall be classified as if they consisted of the material or component which gives them their essential character.” In this case the component that gives heat exchange its essential character is the natural convection coil (Part # COLE-84-0C1H) because the unit cannot function without this component.
We note that the convection coil is composed of more than one metal.
The text above is an excerpt. The official ruling, with its letterhead, signature and any attachments, is on CBP CROSS (N365179).