The tariff classification of continuous glucose monitoring sensors from Canada
No revocation or modification of this ruling appears in the Customs Bulletin issues read here (Nov 6, 2024 through Nov 18, 2026), where CBP publishes most such actions. That is not confirmation that the ruling is still in effect. Confirm its status with CBP before relying on it (ruling on CBP CROSS).
Ruling text
In your letter dated October 2, 2025, you requested a tariff classification ruling. Descriptive literature was provided for our review. The item under consideration is described as the Dexcom G6 Continuous Glucose Monitoring (CGM) sensor, which is a single-use, sterile, electrochemical sensor designed to measure glucose levels in interstitial fluid. The sensor is intended for subcutaneous insertion in human patients for a period of up to 10 days.
It forms part of a larger continuous glucose monitoring system used by patients with diabetes. The complete system includes the sensor, a transmitter (a reusable component that attaches to the sensor and sends the glucose data wirelessly to the display device), and a display (which can be a dedicated Dexcom receiver or a compatible smartphone or smartwatch that shows the glucose readings and trends).
The sensor is used exclusively for medical purposes, specifically to provide continuous glucose readings to individuals with diabetes, thereby aiding in blood glucose management. The Dexcom G6 CGM Sensor is a Class II Medical Device. The sensor consists of a small wire filament coated with enzymes (glucose oxidase) inserted beneath the skin. The housing is composed of plastic and adhesive backing for secure skin placement.
The sensor connects to the Dexcom G6 transmitter (not included in this request) which wirelessly relays data to a compatible receiver or smartphone. The sensor itself contains no significant metal or precious components; it is primarily medical-grade plastics, adhesives, and a thin enzyme-coated filament. The sensors are imported in boxes of 3 units, sterile, and individually sealed. We consider the Dexcom G6 CGM sensor to be a part of the overall Dexcom G6 CGM system as it cannot be used by itself.
Additionally, the sensor must be used with the G6 transmitter and cannot function with any other transmitter or system.
Therefore, according to Chapter 90 Note 2(b), the applicable subheading for the Dexcom G6 CGM sensor will be 9027.90.5695, Harmonized Tariff Schedule of the United States (HTSUS), which provides for “Instruments and apparatus for physical or chemical analysis (for example, polarimeters, refractometers, spectrometers, gas or smoke analysis apparatus); instruments and apparatus for measuring or checking viscosity, porosity, expansion, surface tension or the like; instruments and apparatus for measuring or checking quantities of heat, sound or light (including exposure meters); microtomes; parts and accessories thereof: Microtomes; parts and accessories: Parts and accessories: Of electrical instruments and apparatus: Other: Of instruments and apparatus of subheading 9027.20, 9027.30, 9027.50, 9027.81 or 9027.89: Other.” The general rate of duty will be free.
Products of Canada as provided by heading 9903.01.10 in Section XXII, Chapter 99, Subchapter III, U.S. Note 2(j), HTSUS, other than products classifiable under headings 9903.01.11, 9903.01.12, 9903.01.13, 9903.01.14, and 9903.01.15, HTSUS, will be subject to an additional 35 percent ad valorem rate of duty. At the time of entry, you must report the applicable Chapter 99 heading, i.e.
The text above is an excerpt. The official ruling, with its letterhead, signature and any attachments, is on CBP CROSS (N354553).