The tariff classification of parts of surgical devices from Costa Rica.
No revocation or modification of this ruling appears in the Customs Bulletin issues read here (Nov 6, 2024 through Nov 18, 2026), where CBP publishes most such actions. That is not confirmation that the ruling is still in effect. Confirm its status with CBP before relying on it (ruling on CBP CROSS).
Ruling text
In your letter dated April 3, 2026, you requested a tariff classification ruling, on behalf of your client, AVNA. The items under consideration are Part No. 3013-4, the “inner sleeve” of the articulation joint; Part No. 3013-6, the circular collar/flange-like part with an extended tab, which you described as “nut”; and Part No. 4210-2, the hollow, bobbin-shaped aluminum part. Part No. 3013-4, and Part No. 3013-6, are stainless-steel parts of the articulation joint in the Signia Stapling System.
Manufactured to the precise specifications and tolerances required for surgical instruments, these parts are welded together to form the joint that connects the adapter to the power handle. This articulation joint enables the adapter to articulate and rotate, allowing the system to cut and staple tissue effectively during surgical procedures.
Part No. 4210-2 is a hollow, bobbin-shaped aluminum component part that functions as the interface joint between the shaft and actuator handle of the Ligasure XP Jaw Sealer/Divider. It enables 360 degrees rotation of the shaft, allowing for precise positioning of the surgical jaws during procedures. This part is one of two components in a two-part assembly within the device; the second part is not included in this request.
The Signia Stapling System and Ligasure XP Jaw Sealer/Divider are devices used by medical professionals during surgical procedures. They are marketed and sold exclusively to healthcare providers and are specifically designed for minimally invasive surgeries. These devices are intended solely for surgical applications: the Signia Stapling System for cutting and stapling tissue, and the Ligasure XP Jaw Sealer/Divider for dissecting, sealing, and dividing vessels.
Your submission proposed classifying parts of medical devices under subheading 9018.90.8000 of the Harmonized Tariff Schedule of the United States (HTSUS), which covers other instruments and appliances used in medical, surgical, dental or veterinary sciences and parts and accessories thereof. While we agree that these parts belong in heading 9018, we disagree with the subheading you suggested.
The Signia Stapling System is battery powered, therefore it uses electricity to power its function and considered as “electro-medical” under subheading 9018.90.75, HTSUS, not under the “Other” category of subheading 9018.90.80, HTSUS. Additionally, the Ligasure XP Jaw Sealer/Divider uses high-frequency radio frequency electric currents for its function, which, as explained in HQ H152456, qualifies it as “electro-surgical apparatus.” Thus, it should be classified under subheading 9018.90.60, HTSUS.
The applicable subheading for Part No. 3013-4 and Part No.