No revocation or modification of this ruling appears in the Customs Bulletin issues read here (Nov 6, 2024 through Nov 18, 2026), where CBP publishes most such actions. That is not confirmation that the ruling is still in effect. Confirm its status with CBP before relying on it (ruling on CBP CROSS).
Key passages, quoted from the ruling
- The applicable subheading for the F2 Door Assembly, F2 Coolant Trough Assembly, F2 Coolant Intake Assembly and F2 Basin Assembly will be 9018.49.8080, Harmonized Tariff Schedule of the United States (HTSUS), which provides for "other" instruments and apparatus used in medical, surgical, dental or veterinary sciences, and parts and accessories thereof.
Ruling text
In your letter dated May 22, 2026, you requested a tariff classification ruling. The items under consideration include the F2 Door Assembly, F2 Coolant Trough Assembly, F2 Coolant Intake Assembly and F2 Basin Assembly, which are subassemblies of a compact dental milling machine, Fastmill.io (addressed under a separate cover in NY N361752). A separate ruling will address the F2 LED Assembly.
As you noted in your submission, all of these parts do not have independent functions outside of the milling system and are used exclusively for the operation, control or mechanical functioning of the dental milling machine. The F2 Door Assembly is a subassembly of the dental milling machine. It consists of a plastic door that encloses the cutting area and features a window for viewing the restoration process.
The door mounts to a multi-piece sheet metal frame, which provides proper alignment and includes features for attaching to guide rails during final assembly. The F2 Coolant Trough Assembly is a subassembly of the dental milling machine that serves as the main reservoir for the coolant. The coolant recirculates through the machine to cool and lubricate the grinding process during dental restoration production.
The assembly includes two baskets with mesh screens to filter larger particulates at the coolant entry and exit points. A small metal “flag” interacts with another assembly to detect when the trough is properly inserted. The assembly consists of four injection-molded plastic components and one sheet metal component.
The F2 Coolant Intake Assembly is a subassembly of the dental milling machine used to monitor the coolant level and draw coolant from the trough, serving as the intake for the coolant recirculation system. It features a linkage system that mechanically connects to the coolant trough drawer, allowing the level sensor and intake tube to move in or out of the trough as the drawer is opened or closed. This subassembly consists of multiple sheet metal, plastic injection, and buyout components.
The F2 Basin Assembly is a subassembly of the dental milling machine that contains the basin, where the spindle and dental material interact and dental restorations are created. It includes a sheet metal housing that secures the basin and mounts it to the main structure of the machine, as well as seals to prevent the coolant from escaping during grinding. The assembly also incorporates belts and pulleys for opening and closing the door that covers the large front opening of the basin.
The applicable subheading for the F2 Door Assembly, F2 Coolant Trough Assembly, F2 Coolant Intake Assembly and F2 Basin Assembly will be 9018.49.8080, Harmonized Tariff Schedule of the United States (HTSUS), which provides for "other" instruments and apparatus used in medical, surgical, dental or veterinary sciences, and parts and accessories thereof. The general rate of duty will be free. The duties cited above are current as of this ruling’s issuance.