The tariff classification of a Dual Channel Power Supply Module from Malaysia
No revocation or modification of this ruling appears in the Customs Bulletin issues read here (Nov 6, 2024 through Nov 18, 2026), where CBP publishes most such actions. That is not confirmation that the ruling is still in effect. Confirm its status with CBP before relying on it (ruling on CBP CROSS).
Ruling text
In your letter dated April 1, 2025, you requested a tariff classification ruling. Descriptive literature was provided for our review. The item under consideration is described as the Dual Channel Power Supply Module (Model MPSU50-2ST), which is designed to provide a wide range of voltage outputs to address the testing and characterization of components, circuits, modules, and other devices. The power supply module is used in research laboratories, design and development, and environmental stress screening.
The Dual Channel Power Supply Module is designed to be incorporated into the MP5103 mainframe, which has three module slot bays for accepting a host of various power supply unit (PSU) Instrument Modules. This allows the user to build up a system that enables them to address every changing testing need. The MPSU50-2ST cannot be integrated into other products that contain embedded power supplies and is therefore considered unique to this testing system.
The power supply is programmed through the use of ACSII text commands that are sent from a controller to the MP5103 mainframe. These commands control the source levels and output state of the power supply. The power supply module is programmable within the range of -50 V to +50 V. The bipolar output allows users the ability to program positive or negative voltage/current without having to physically switch the test leads. By default, the power supply module does not provide a voltage output when powered on.
The user connects the device under test to the output terminals of the power supply module. From the front panel, the user selects the slot option, which displays control settings for the installed module. The user then sets the desired voltage level to be applied to the device. Next, the user sets the current draw limit, over voltage and over current protection values, which are all means to limit the output to the device under test.
The user then turns the output on, and the set voltage is applied to the device under test. Measurements of the current draw and readback of the voltage source is displayed on the front panel. The output of the power supply module will remain active until the user turns it off. The device is not supplying power to any other instruments. Its output is directly connected to the device under test in conjunction with determining if it is defective in various ways.
We find the Dual Channel Power Supply Module (Model MPSU50-2ST) to be substantially similar to the devices in New York Ruling Letter N233192 (dated October 10, 2012) and Headquarters Ruling Letter 962897 (dated November 24, 1999), which have been previously issued to Tektronix, Inc. In both rulings, CBP found the devices to be classified in heading 9030, Harmonized Tariff Schedule of the United States (HTSUS).
The text above is an excerpt. The official ruling, with its letterhead, signature and any attachments, is on CBP CROSS (N347345).