The tariff classification of a crude cooler module from Canada
No revocation or modification of this ruling appears in the Customs Bulletin issues read here (Nov 6, 2024 through Nov 18, 2026), where CBP publishes most such actions. That is not confirmation that the ruling is still in effect. Confirm its status with CBP before relying on it (ruling on CBP CROSS).
Ruling text
In your letter dated May 15, 2025, you requested a tariff classification ruling on behalf of your client, Santos Limited – Oil Search (Alaska). The merchandise under consideration is identified as the 241 Crude Cooler Exchanger Module which will be incorporated into the Nanushuk Processing Facility, a modular plant currently under construction in Alaska. When construction is complete, this facility will process oil deposits from the Nanushuk reservoir into sales quality oil.
The function of the 241 Crude Cooler Exchanger Module is to cool crude oil before it enters a downstream module. Its main components include a sales oil mixer, four crude coolers, piping, valves, instrumentation and controls. Other components include exhaust fans, fan motors, building heaters, and heater motors. As the Nanushuk Processing Facility is in Alaska, the building heaters and exhaust fans are included to heat the module building and provide air circulation. They do not have an impact on fluid processing.
The four crude coolers will be configured as steel shell and tube heat exchangers, where treated crude oil flows into the shell side of the unit and cold medium flows through the tube side of the heat exchanger. The two fluids do not mix as they move through the unit, with the crude oil exiting at a lower temperature and the cold medium exiting at a higher temperature. Connected downstream to the crude coolers is an oil sales mixer that turns the crude oil into a homogenized mixture as it exits the module.
The mixer is not mechanical but described as a carbon steel plate with a specially shaped opening. In your request, you suggest the 241 Crude Cooler Exchanger Module is classifiable under subheading 8419.50.5000, Harmonized Tariff Schedule of the United States (HTSUS). We agree. The module is imported in a single shipment with interconnected components and classified pursuant to Note 4 to Section XVI.
Note 4 covers machines consisting of separate components that are intended to contribute together to a clearly defined function. Here, the components contribute together to perform a function covered by heading 8419, i.e., the treatment of materials by a process involving a change of temperature.
Regarding the subheading, General Rule of Interpretation (GRI) 6 requires that the classification of goods in the subheadings of headings shall be determined according to the terms of those subheadings, any related subheading notes, and to the GRIs. We note that the crude oil is only treated within the shell and tube heat exchangers and exits the module without any other processing.
The text above is an excerpt. The official ruling, with its letterhead, signature and any attachments, is on CBP CROSS (N349078).